How PSA Technology Works

Balston Monobed and Dual Bed Nitrogen Generators produce up to 99.9995% pure, compressed nitrogen at dewpoints to -70°F (-21°C) from nearly any compressed air supply.  The generators are designed to continually transform standard compressed air into nitrogen at safe, regulated pressures without operator attention. 

Balston PSA Nitrogen Generators utilize a combination of filtration and pressure swing adsorption technologies.  High efficiency prefiltration pretreats the compressed air to remove all contaminants down to 0.1 micron. Air entering the generator consists of 21% oxygen and 78% nitrogen. The gas separation process preferentially adsorbs oxygen over nitrogen using carbon molecular sieve (CMS). At high pressures the CMS has a greater affinity for oxygen, carbon dioxide, and water vapor than it does at low pressures.  By raising and lowering the pressure within the CMS bed, all contaminants are captured and released, leaving the CMS unchanged. This process allows the nitrogen to pass through as a product gas at pressure.  The depressurization phase of the CMS releases the absorbed oxygen and other contaminant gases to the atmosphere.

 

Model Number

DB-5, DB-10  DB-15, DB-20
Model # w/ Oxygen Analyzer DBO-5, DBO-10 DBO-15, DBO-20
Nominal Conditions 
..Feed Pressure (minimum)  110 psig  110 psig 
..Temperature  80°F  80°F 
..Ambient Pressure  1 Atm.  1 Atm. 
Compressed Air Specifications 
..Maximum Pressure  140 PSIG  140 PSIG 
..Temperature Range  60°F - 105°F  60°F - 105°F 
..Dewpoint  40°F atmospheric dewpoint or better  40°F atmospheric dewpoint or better 
..Residual Oil Content Trace  Trace 
..Particles  <.01 micron  <.01 micron 
Atmospheric Dewpoint 
..Atmospheric Dewpoint  -58°F (-50°C) -58°F (-50°C)
..Commercially Sterile  Yes Yes
..Particles > .1 micron  None None
..Suspended Liquids  None None
..Recommended Inlet Pressure (Min.)  110 psig (7.6 barg) 110 psig (7.6 barg)
..Max Inlet Pressure  140 psig (9.7 barg) 140 psig (9.7 barg)
..Max Outlet Pressure (Based on
  nominal conditions and standard
  60 gallon nitrogen tank) 
80psig DB-15: 80 psig @ 95-99.99% Purity
DB-20: 80 psig @ 98-99.99% Purity
70 psig @ 95-94% Purity
75 psig @ 95-96% Purity 
..Min. / Max. Ambient Temperature 40°F/95°F (4°C/35°C) 40°F/95°F (4°C/35°C)
Ambient Conditions
..Temperature 45°F - 95°F 45°F - 95°F
..Min/Max Ambient Temperature 40°F - 95°F 40°F - 95°F
..Ambient Pressure Atmospheric Atmospheric
..Air Quality Clean air without contaminants Clean air without contaminants
Dimensions, Weight and Connections 
..Dimensions 28.5”L x 32.25”D x 78”H 28.5”L x 50”D x 78”H
..Weight (with tank) 620 lbs (DB-5), 830 lbs (DB-10) 1240 lbs (DB-15), 1450 lbs (DB-20)
..Inlet 1/2” NPT 1” NPT
..Outlet 1/2” NPT 3/4” NPT 
..Electrical Requirement 120VAC/60Hz, 1.5 Amp 120VAC/60Hz, 1.5 Amp

 

Flow Rates (SCFH)
% Nitrogen DB-5 DB-10 DB-15 DB-20
99.999 33 66 99 132
99.995 74 148 222 296
99.99 141 281 421 561
99.95 204 409 613 817
99.9 240 480 720 960
99.5 345 689 1034 1378
99 416 831 1247 1663
98 499 998 1496 1995
97 570 1140 1710 2280
96 630 1259 1889 2518

 

Call 800-752-9055 for literature and pricing or to make an appointment to have a salesman visit your site.  If you prefer to ask for information via the internet use the "REQUEST INFO" button above or e-mail = sales@rjmsales.com.