Specifications
  Fluke TiS
.Imaging Performance
.Standard infrared lens: Field of View (FOV) 17° horizontal x 17° vertical
....Spatial resolution (IFOV) 2.50 mRad
....Minimum focus distance 15 cm (approx. 6 in)
.Image capture frequency 9 Hz refresh rate
....Thermal sensitivity (NETD) ≤ 0.1 °C at 30 °C target temp. (100 mK)
....Infrared spectral band 7.5 µm to 14 µm (long wave)
....Focus mechanism Versatile, one-handed Manual Focus
....Detector type 120 x 120 Focal Plane Array, uncooled microbolometer
..Display 9.1 cm (3.7 in) diagonal landscape color VGA (640 x 480) LCD with backlight and clear protective cover
.Temperature measurement
.Temperature Range (not calibrated below -10 °C) -20 °C to +100 °C (-4 °F to +212 °F)
.Temperature Measurement Accuracy ± 5 °C or 5 % (at 25 °C nominal, whichever is greater)
.Image presentation
.Pallettes Ironbow, Blue-Red, Grayscale
.Level and span Smooth auto-scaling and lock of level and span
.Minimum span (in auto mode) 5 ºC (9 ºF)
.Image capture and data storage
.Image capture, review and save mechanism One-handed image capture, review, and save capability
.Storage medium SD Memory Card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR or 3000 basic bitmap (.bmp) images,  transferrable to PC via included multi-format USB card reader).
.File formats Non-radiometric (.bmp) or fully-radiometric (.is2). No analysis software required for non-radiometric (.bmp) files
.Export file formats w / SmartView software BMP, DIB, GIF, JPE, JFIF, JPG, PNG, TIF and TIFF
.Memory Review Sequential image navigation and review
.Software SmartView; Full analysis and reporting software included
Controls and adjustments
.Set-up controls User selectable temperature scale (°C/°F),
Language selection
Time/Date set
User selectable backlight: "Full Bright" or "Auto"
.Language selection English, German, French, Spanish, Portuguese, Italian, Swedish, Finnish, Russian, Czech,
Polish, Turkish, Simplified Chinese, Traditional Chinese, Korean and Japanese (Dutch and Hungarian in manual only)
.Power
.Battery type Internal rechargeable battery pack (included)
.Battery life Three to four hours continuous use (assumes 50% brightness of LCD)
.Battery charge time 2.5 hours to full charge
.AC battery charging AC adapter/charger (110VAC to 220VAC, 50/60Hz) (included), charges battery while imager is operating or turned off, AC mains adapters included
.AC operation AC operation with included power supply (110VAC to 220VAC, 50/60Hz). AC mains adapters included.
.Power saving Sleep mode activated after five minutes of inactivity, automatic power off after 30 minutes inactivity.
.Environmental and mechanical design
.Operating temperature -10 °C to +50 °C (+14 °F to +122 °F)
.Storage temperature -20 °C to +50 °C (-4 °F to +122 °F) without batteries
.Relative humidity Operating and storage 10 % to 95 %, non-condensing
.Enclosure rating IP54 (protected against dust, limited ingress; protection against water spray from all directions)
.Safety standards CSA (US and CAN): C22.2 No. 61010-1-04, UL: UL STD 61010-1 (2nd Edition). ISA: 82.02.01
.Electromagnetic compatibility Meets all applicable requirements in EN61326-1:2006
.C Tick IEC/EN 61326-1
.US FCC CFR 47, Part 15 Class B
.Vibration 0.03 g2/Hz (3.8 grms), IEC 68-2-6
.Shock 25 g, IEC 68-2-29
.Drop 2 meters (6.5 feet)
.Protective lens cover Yes
.Weight (including battery) 1.2 kg (2.6 lbs)
.Size (HxWxL) 26.7 cm x 12.7 cm x 15.2 cm (10.5 in x 5.0 in x 6.0 in)
.Other
.Warranty Two-years (standard)
.Recommended calibration cycle Two-years (assumes normal operation and normal aging)