...BENEFITS:
|
| How The Technology Works Parker Balston Nitrogen Generators utilize proprietary membrane separation technology. The membrane divides the air into two streams: one is 95%-99.5% pure nitrogen, and the other is oxygen-rich with carbon dioxide and other trace gases. The generator separates air into its component gases by passing inexpensive, conventional compressed air through bundles of individual hollow fiber, semi-permeable membranes. Each fiber has a perfectly circular cross section and a uniform bore through its center. Because the fibers are so small, a great many can be packed into a limited space, providing an extremely large membrane surface area that can produce a relatively high volume product stream. Compressed air is introduced to the center of the fibers at one end of the module and contacts the membrane as it flows through the fiber bores. While oxygen, water vapor and other trace gases permeate the membrane fiber and are discharged through a permeate port, the nitrogen is contained within the hollow fiber membrane, and flows through the outlet port of the module. Water vapor also permeates through the membrane; therefore, the nitrogen product gas is very dry. Savings and Convenience Easy To Operate And Maintain Installation consists of simply connecting a standard compressed air line to the inlet and connecting the outlet to a nitrogen line. The membrane systems offer the advantages of no moving parts and no electrical requirements. There is no complicated operating procedure to learn or labor intensive monitoring involved. Simply select the purity your process requires, set the flow and pressure, and within minutes high purity, dry nitrogen is available for use! Once the system is operating, it requires little monitoring. The only maintenance involves changing the coalescing filter cartridges and activated carbon filter annually. This is a simple ten minute procedure. Nitrosource Series Nitrogen Generators: |
| ......Flow Rate (SCFM) @100 psig @68ºF with corresponding N2 Purity Levels | ||||||
|
..Model |
99.5% | 99% | 98% | 97% | 96% | 95% |
| ..Main Unit | 210 | 330 | 570.4 | 780.5 | 990.6 | 1,200.7 |
| ..NS-1 | 420 | 660 | 1,140.7 | 1,561 | 1,981.2 | 2,401.5 |
| ..NS-2 | 630 | 990 | 1,711.1 | 2,341.5 | 2,971.8 | 3,602.2 |
| ..NS-3 | 840 | 1,320 | 2,281.4 | 3,121.9 | 3,962.5 | 4,803 |
| ..NS-4 | 1,050 | 1,650 | 2,851.8 | 3,902.4 | 4,953.1 | 6,003.7 |
| ..NS-5 | 1,260 | 1,980 | 3,422.1 | 4,682.9 | 5,943.7 | 7,204.5 |